How do plc timers work
A TOFF timer will keep the output energized for a preset time after the rung signal has gone false. When the rung timer is true, the output will be true without any delay. When the rung signal becomes false the timer starts operating. The timer starts accumulating times when the rung condition becomes true, until the accumulated value becomes equal to the Preset value.
The output turns off when the output will turn false when the accumulated value equals the preset value. A retentive timer is used when you want to retain accumulated time value through the power loss or the change in the rung state. Timer a ccumulated value. The timer accumulated value is the number that shows how long the timer has been timing. Timer e nabled bit. The timer enabled bit will be on when the timer is enabled. Timer t iming bit. The timer timing bit will be on when the timer is timing.
Timer d one bit. PLC timer examples. On-delay timer. For the first example, I will talk about the on-delay timer. Type the timer file name Timer1. This PLC on-delay timer is now set up and ready to use. How does an on-delay timer work? On-delay timer applications. Another on-delay timer could also be set up to sound a conveyor start-up warning horn and light. Off-delay timer.
How does an off-delay timer work? Off-delay timer applications. Retentive on-delay timer. The firmware is what makes the PLC work. It is this piece of software that does the whole scan cycle of the PLC — puts the state of the inputs into memory registers , runs your program and sets the outputs via the output memory registers.
The scan cycle takes some time often around 20 ms and it is only in the first step of the scan cycle that the inputs are detected. If you turn on the input right after the PLC has scanned the inputs it can take a whole scan cycle before the input is detected as on. Output errors also happens because of the scan cycle. If the output is set right after the scan cycle where the PLC writes the output register, it can take a whole scan cycle before the output is actually set in the register.
When you sum up the input and output errors you will get what is called the total software error. You will often see even experienced PLC programmers overlook this source of errors. It is so important for PLC programmers not only to know about PLC programming, but also to know about electronics and hardware.
Because of how the hardware works it can generate errors both at the inputs and at the outputs of a PLC. This filter is actually a small delay, that makes sure the short spikes will not get detected at real inputs. When you press a button and turn on e. The signal will jump up and down and without the filter the PLC might detect that as not just one press but multiple presses on the button. If you connect an oscilloscope at the input you can see that bouncing.
Filtering out the bouncing and noise will also give a delay from the timer input is turned on to when the PLC actually detects that it is turned on.
On the output side you can also have errors. They happen because of the output electronics. If you have a relay output it can actually take up to 10 milliseconds for the relay to close. Transistors such as NPN transistors are a little better but could still take up to 1 ms to fully close. It is used when rung state change, power loss or any device interruption occurs. When its rung goes from false to true, the Accumulate value of the retentive timer counts from where it stopped the last time.
The reset instruction will be activated when its rung is true and resets the timer according to the address assigned to the reset instruction. The retentive timer must be reset with a different signal for the reset time. And it indicates that the clock has reached its preset time. We can set the value in T0 to T ranges. In the Siemens, LD program can be written with the five types of timers. Where T4 is the type of file.
Addressing format with the three status bits for timer instruction.